品牌
经销商厂商性质
成都市所在地
A-169 碳钢虹吸
面议Dwyer FR,FRL系列 过滤/减压/润滑器
面议Dwyer A-464型Magnehelic差压表嵌入式安装架
面议Dwyer MTL5041/5045系列 隔离栅
面议KIMO 热线式风速温度变送器CTV115
面议KIMO 便携式温湿度仪HD 110
面议setra西特 室内压力显示仪 (型号 SRPD)
面议KIMO MP 115/MP 112便携式差压仪
面议KIMO MP 110/MP 111便携式差压仪
面议Dwyer FC-1000型 风机速度自动调节器
面议Dwyer LCI108,LCI108J系列 多功能数显表
面议Dwyer LCI132系列 多功能数显表
面议The Mercoid® Series 3100 Smart Pressure Transmitter is a microprocessor-based high performance transmitter, which has flexible pressure calibration, push button configuration, and programmable using HART® Communication. The Series 3100 is capable of being configured for differential pressure or level applications with the zero and span buttons. A field calibrator is not required for configuration. The transmitter software compensates for thermal effects, improving performance. EEPROM stores configuration settings and stores sensor correction coefficients in the event of shutdowns or power loss. The Series 3100 is FM approved for use in hazardous (classified) locations. The 100:1 rangeability allows the smart transmitter to be configured to fit any application.
Service: Compatible gases, steam, liquids or vapors.P/1.
Wetted Materials: 316L SS.
Accuracy: ±0.075% FS (@ 20°C).
Rangeability: 100:1 turn down.
Stability: ±0.125% FSO/yr.
Temperature Limits: Process: -40 to 248°F (-40 to 120°C); Ambient (without LCD): -40 to 185°F (-40 to 85°C); Ambient (with LCD): -22 to 176°F (-30 to 80°C).
Pressure Limits: Max. pressure: Range: -14.5 to 2000 psi; Burst pressure: 10000 psi.
Thermal Effect: ±0.125% span/32°C.
Power Requirements: 11.9 to 45 VDC.
Output Signal: 4 to 20 mA/HART® Communication.
Response Time: 0.12 seconds.
Damping Time: 0.25-60 seconds.
Loop Resistance: Operation: 0 to 1500 Ohm; HART® Communication: 250 to 500 Ohm.
Electrical Connection: Two 1/2" female NPT conduit, screw terminal.
Process Connection: 1/4" female NPT.
Display: Optional 5 digit LCD.
Enclosure Rating: NEMA 4X (IP66) and explosion-proof for Class I, Div I, Groups A, B, C and D.
Weight: 8.6 lb (3.9 kg).
Agency Approvals: CE, FM.
ACCESSORIES:
| ||
• Completely configurable using zero/span buttons (no calibrator required) • Rangeability (100:1) • High accuracy (0.075%) • Automatic ambient temperature compensation • Fail-mode process function • Selectable engineering units |