紫外检测器原理与性能介绍:
紫外可见检测器
波长范围:190-400nm(氘灯),400-800nm(钨灯)
波长精度:±2nm
重 复 性:± 0.2 nm
基线噪声:±10e-5 au,230 nm
基线漂移:5x10e-4au/h,230 nm时间常数:0.02s,0.1s,0.5s,1s,2s
uv absorbance detection is the most popular form of detection. more than 50 % of all ce systems are equipped with uv absorbance detectors. among the advantages of uv-vis detectors are simplicity of use and the fact that almost any compound can be detected by uv absorbance, either direct or indirect. typical limits of detection are 1 to 10 μm for compounds that show considerable absorbance at least one wavelength. out of many uv-vis detectors that are used in combination with prince, prince technologies offers one of the most sensitive detectors, the lambda 1010 uv-vis detector.
some features of the lambda 1010 uv-vis detector
simple operation conditions and compact designthe lambda 1010 is a programmable uv/vis detector for ce. the advanced technology and the user-friendly design of the instrument generate superb results in routine and more sophisticated chromatographic applications.
high sensitive special designed ce cell by prince technologiesin general capillaries used have an outer coating of polyimide for flexibility. this coating is not uv transparent. for good measurements, a small window for detection is made on the capillary, most often by burning the coating and cleaning with alcohol.
for reproducible measurements it is necessary that the light beam is always focused on the centre of the capillary. therefore the ce cell has been designed with a slit, capturing the capillary at the window. with this capturing, a ball lens is positioned to have the optimum light intensity inside the capillary, giving the best signal results. because of this design, a reproducible installation from capillary to capillary is easily achieved. actually, by checking the light intensity going through the capillary itself, it is possible to position the window of the capillary at the light beam and optimise for small deviations in the window performance.
wavelength switchingfor analyses of compounds which differ in their l max. and/or in concentration and therefore in the absorbance at the peak maximum, it is useful to switch the detection wavelength and the range during the run according to the migration time of the compound. for complex mixtures the lambda 1010 offers switching of wavelength.
detection at the absorbance maximumto detect unknown compounds at their maximum absorbance, it is recommended to use the l max. wavelength. the lambda 1010 offers the possibility to measure the uv-spectra of peaks during the run without stop-flow. measuring first the absorbance of the background electrolyte and then the spectra of the separated compounds you will obtain the peak spectra by a subtraction process.
on column measurementusing capillary columns, there is the need to detect directly on-column to avoid peak broadening and any other extra column effect. this is possible with the capillary ce cell of the lambda 1010 where the fused silica separation capillary is mounted in the light beam. the capillary ce cell for the lambda 1010 is retrofitable. an additional calibration of the detector to adapt the ce cell is not needed. the self aligning optics of the capillary flow cell guarantee the adjustment of different capillary diameters to the optics of the detector.
due to the small illuminated volume, the low noise of ±2x10-5 au, and the high separation efficiency of cze, the mass-sensitivity for uracil is approx. 1 pg. the capillary acts like a cylindrical lens and gives extraordinarily good linearity for the detector with absorbance < 0.1 aufs.
|
specification details wavelength with deuterium lamp (standard) 190 - 400 nmwith halogen lamp (option) 400 - 800 nm optical bandwidth 6 nm wavelength accuracy ± 2 nm wavelength reproducibility ± 0.2 nm measuring range incremental by 0.001 0.001 - 1.999 au noise at 230 nm, cell filled with water ± 10-5 au baseline drift at constant temperature, at 230 nm 5.10-4 au/h auto zero range -0.1 to +1.999 au time constants 0.02 s, 0.1s, 0.5 s, 1 s and 2 s recorder output 100 mv integrator output 1 v marker internal +10 mv, external +5 mv external control via rs 232 ce flow cell special lambda ce-cell for uv-vis detector power requirement 115/230 v ± 10%, 50/60 hz, 55 va operating dimensions 483 x 255 x weight